Low Voltage Switchgear

  • Description
  • Reviews (0)

Description

Low Voltage Switchgear

IEM’s unique approach to engineering and manufacturing allows us to assemble products that meet specialized dimensional and electrical requirements.

 Our flexible capabilities allow for the selection of industry leading components including control and measuring devices, allowing for a superior, fully customizable control and monitoring electrical assembly. This is just one element of IEM’s superior control solutions to provide protection and operational reliability for any quality power distribution assembly.

 Depending on the users’ technical and physical requirements, UL 1066 power circuit breakers can be mounted in a fixed or drawout configuration. Indoor, outdoor non walk-in enclosures are available in an extensive selection of durable color finishes.

Voltage: 240V to 600V

Ampacity: 800A to 5000A

Up to 200kA at 480V and up to 100kA at 600V

Available in NEMA 1 and NEMA 3R outdoor enclosures

UL 1558 Listed

UL 1066 Circuit Breaker

Through the door breaker operation

Circuit breakers of like frame sizes and interrupting ratings are interchangeable.

Front accessibility to control and communication wiring

Isolated access to all wiring

All breakers have unique drawout design allowing for through-the-door racking

Short-circuit withstand rating up to 100kA/ 85kA (600V)

Circuit breakers are available in various levels of interrupting ratings from 42–200 kA up to 480 volts and 100kA up to 600V

Bolted copper bus provided as standard

Large rear cable compartment pull area allowing maximum room for power cables

Bus provision for future equipment expansion

System designed for maximum uptime with low maintenance

Modular circuit breaker designed for easy addition of control accessories

Paint ANSI 61 – standard, other colors available as option

 

IEM Difference

All enclosures are designed for specific application with improved dimensional flexibility and finished using state of the art powder coating system providing an indoor finish that exceeds the 1500 hour salt spray testing requirement for outdoor equipment to 3000 hours.

 Component and metering selections are based on value engineering for the application and optimized to meet specifications.

Technical Specifications

IEM Low Voltage switchgear meets or exceeds applicable standards including ANSI C37.20.1.

IEM Low Voltage switchgear meets seismic testing, circuit requirements as outlined by IEEE344 and ICC-ES-AC156.

Reviews

There are no reviews yet.


Be the first to review “Low Voltage Switchgear”