 VRLA Deep Cycle Battery 12 Volts 200Ah for Solar Power Off Grid Systems

 

Detailed Product Description

Usage: Solar Power,telecom Voltage: 12v
Capacity: 200Ah(10Hr) Maintenance Type: Free
Size: 522*240*219mm Weight: 60.00kg
Container Material: ABS Terminal Type: Cooper,lead
Application Type:: Cycle Use Alternative Name: Solar Battery

12 volts VRLA Deep Cycle Battery , 200Ah Solar Power Deep Cycle Battery

DEEP CYCLE BATTERIES ARE REQUIRED FOR SOME TYPES OF SOLAR PANEL SYSTEMS
Solar Batteries (Deep Cycle Batteries) are a key component in a stand-alone renewable energy system. If you are installing a wind, solar panel or hydro electric system that will be tied to your utility grid, you will still need deep cycle batteries if you are trying to use power in the event of an outage. Without deep cycle batteries, you can only use power at the time you produce it (i.e. you will not have power when the sun isn’t out if you don’t have batteries in your solar electric system).

In renewable energy systems, deep cycle batteries provide the energy storage for your system. Unlike your car battery, deep cycle batteries that are used in renewable energy applications are meant to be discharged and recharged (cycled) repeatedly. To maintain healthy batteries and prolong battery life, most manufacturers suggest limiting the depth of discharge to about 20%. (That means the deep cycle batteries will be at 80% capacity or better.) At the very least, do not allow the batteries to be discharged below 50% Depth of Discharge (DOD). Often an inverter will have a Low Voltage Disconnect feature that will disconnect loads at a given set point. Low voltage alarms can provide audible warnings as well. Ammeters, Voltmeters, Battery Monitors can help better maintain deep cycle battery health and provide statistics about the overall health of the system.

  1. Long shelf life
    Can be stored for a long time period and no need to recharge during storage .Battery left-over capacity can be as high as 70% after being stored for 1 year and can be restored to 85% of its full capacity when fully recharged.
  2. Over discharge performance under low voltage
    This battery can be restored to 80% of its full capacity while others only being rendered to failure because of the sulfuration of the sulphur-acid and its consequent maintenance, after subject to long period of repeated over –discharging due to frequently engine igniting, lighting and insufficient charge for the battery caused by short distance driving and low speed
  3. Over discharge performance under high voltage
    Being charged at 16V(not recommended ,though),this battery can be as high as 95% of its full capacity, no drying up in the electrolyte due to little gas releasing and all released gas being absorbed by the plates, while this kind of sealed lead-acid battery usually being charged by a external 14.8V charger which being designed with different emphasis between amperage and voltage(because the charge voltage for flooding lead acid battery is usually at 16V,so the prevalent charge voltage is 16V),it will be soon rendered useless caused by drying out of the electrolyte if the ordinary battery being charged by a 16V external charger.
  4. Quick charge acceptance
    This battery can quickly absorb the momentary charging energy generated by vehicle _borne generator and braking, testing date shows that it can absorb 70% of the energy released while others only 40%,after being charged under this kind of condition for 1 hour.
  5. High multiple rates starting performance
    Small in internal resistance and self-discharge, normal temperature starting discharge multiple rates can be as high as 8C20 while other ordinary battery can only reach 6C20,so this battery can be used to substitute high power battery.
  6. Super long life span
    This battery’s life span is twice as long as ordinary battery’s due to its slow capacity attenuate rate under repeated deep discharge cycles.
  7. Super long life span Battery’s consistency
    The consistency and balanced discharge performance rendered special match for battery working group unnecessary and only need to replace the damaged one in case there is any, thus speeding the responsiveness of post sale service.
Battery Model JPD12-200
Designed Floating life 12 years
Dimensions(mm) Length Width Height Total height
522 240 218 223
Approx Weight 60.00kg
Internal Resistance Full charged at 20℃: 0.0030Ω
Self Discharge <3% per month at 20 ℃
Capacity Affected by Temp.(10Hr) 40 ℃ 20 ℃ 0 ℃ (-15℃)
109% 100% 85% 65%
Charge Voltage (20 ℃) Cycle use Float use
14.4-14.8v max current: 50A 13.6-13.8v